Skip Ribbon Commands
Skip to main content
SharePoint

5K30.25 - V vs I in a Transformer Primary and Secondary

The Web Part cannot find an InfoPath form in the specified location. Either the location does not have an InfoPath form associated with it or it is on a different site collection. Modify the Web Part Properties and select a list or library on the current site.

​5K30.25 - V vs I in a Transformer Primary and Secondary

Preview
SelectSelected
Title5K30.25 - V vs I in a Transformer Primary and Secondary
Objective

Demonstrate the change of inductance and current on the Priamary vs the voltage rise in the secondary of a transformer as the inductance of the transformer is changed

StatusAvailable
Assembly Instructions

Normal operation has one 100W light bulb attached parallel to the primary (plugged into AC switch). A second 100W light bulb is ​hooked to the secondary. When the AC switch is turned on and the variac slowly ramped up, you should see the effect of either the step up or step down values. The comparison is voltage into the first light bulb vs. the voltage into the second light bulb.

Second possible operation is to hook the first 100W light bulb in series with the primary (going through the Volt output of the AC switch). This causes the current to be limited by the light bulb. As a result, the second light bulb will receive less power. The comparison is the limited current output of the first light bulb vs. the voltage output of the second light bulb that is limited by the first.
Setup Time
Operation Time1
Preview Time5
Operation Instructions

Instructions
Turn on the power switch to the transformer assembly with the top core piece removed. Note that the Primary series bulb illuminates brightly and the Secondary bulb does not illuminate at all, as the transformer has very low inductance .Slowly slide the top core across the two ends of the core and note that as the magnetic flux is contained in the core the Primary bulb gets dimmer and the Secondary bulb illuminates.

ExportableYes
Demo on DimeNo
PIRA 200No
Export Instructions (if different)
HazardsNone
Analysis/Information
Category5 Electricity and Magnetism
Subcategory5K - Electromagnetic Induction
Keywordstransformer, inductance, power, primary, secondary
Construction Information
 
  
  
transformer assembly - base with transformer core connector
1
transformer coil - 100T
2
transformer coil - 200T
2
transformer coil - 400T
2
transformer lamination sheet
3
light bulb - 100W
1
light bulb - 40W, incandescent
1
AC power switch - four outlets, with volts/amps breakout
1
banana to AC line plug adapter
1
banana cable
4
danger sign
1
transformer lamination sheet
3
Export Setup - cenco transformer assembly, transformer coils 440, 880, 1600, 3200 turns, lamination sheets, 100W light bulb, 40W light bulb, AC power switch, banana to AC power cord, banana cables, danger sign
1
variac
1